Multi-enzyme cleaning solution (foam free type)

I want to make an inquiry
Product Description

Multi-enzyme cleaning solution (foam free type)

[Main ingredients] Proteolytic enzymes, amylases, lipases, cellulases, etc., with high-efficiency cleaning agents, corrosion inhibitors, etc.

[Features]

1. Can be used in automatic cleaning systems and manual cleaning.

2. This product is a multi-enzyme efficient cleaning agent developed according to the "Technical Specifications for Cleaning and Disinfection of Soft Endoscopes" (2016 edition).

3. Unique concentrated multi-enzyme formula, which can quickly and effectively completely decompose proteins, carbohydrates, mucopolysaccharides, various fats and other pollutants, excellent silicone removal ability.

4. Excellent biofilm removal ability.

5. Excellent ability to clean metal and plastic.

6, non-corrosive, can be used for various equipment, appliances, effectively avoid the corrosion caused by detergent.

7. There is very little foam during use, it is biodegradable and can be poured directly into the sewer without polluting the environment.

[The main purpose]

It is suitable for automatic cleaning systems and manual cleaning. It is used to clean various soft and hard endoscopes, dental instruments, internal and surgical instruments, pipes, rubber, medical plastics, instruments and laboratory utensils.

[Instructions]

● Automatic cleaning machine cleaning: directly put into the cleaning agent injection tank of the machine and adjust the filling ratio (usually 1: 300), just run the program.

● Ultrasonic cleaning: According to the degree of pollution, take an appropriate amount of multi-enzyme cleaning solution and pour it into the ultrasonic tank, and run the program.

● Manual cleaning: Dilute the multi-enzyme cleaning solution to a dilution of 1: 100 to 1: 300 according to the degree of pollution, and put it into the diluted cleaning solution for washing. The jointed instrument is completely opened, the lumen instrument should be injected with the cleaning solution, and the heavily polluted items can be washed under the surface with a soft brush. Rinse with water after removal.

[Dilution ratio]

Pollution degree

Dilution ratio

Soaking time

weight

10.0ml of multi-enzyme cleaning solution per 1L of water (1: 100)

10 minutes

in

5.0ml of multi-enzyme cleaning solution per 1L of water (1: 200)

5-10 minutes

light

3.5ml of multi-enzyme cleaning solution per 1L of water (1: 300)

2-10 minutes

For heavily contaminated and dried utensils, soak for at least 20 minutes at a dilution ratio of 1: 100

[Precautions]

1. The multi-enzyme cleaning solution cannot directly contact the skin and mucous membranes. If it is accidentally contacted, it should be washed with plenty of running water for more than 10 minutes as soon as possible.

2. Operators should wear gloves and goggles.

3. The multi-enzyme cleaning solution should not be in contact with water and other foreign substances before use. It should be used immediately and should not be reused.

4. The suitable water temperature is 20 ℃ -55 ℃, the temperature is lower than 20 ℃, the soaking time should be prolonged, and above 55 ℃, the enzyme activity will decrease.

5. After each use, screw the bottle cap tightly away from light, heat, and cool and tightly sealed.

[Validity Period] 24 months

[Executive Standard] Q/371402AXX031

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待

Enter mobile station

Contact us

Support hotline:0534-2729820

Company Fax:0534-2729826

Technical phone:0534-2729823

Inspectorate Phone:0534-8828001

Company address::No. 5858, west of Chongde Eleventh Avenue, south of Tianya East Road, Dezhou City, Shandong Province